Bilibino

Javascript is required to view this map.
INES-event
INES 2

Radiation overexposure of personnel while performing refuellig activities

A team of plant Centralized Maintenance Service was performing refuelling activities at the unit, which was in planned outage. Personal dosimeter readings after these activities showed that three team members were exposed to doses exceeding those specified in the work order for performing activities in the controlled area (value of 0.4 rem): one worker was exposed to a dose of 9 rem (90 mSv) exceeding the annual maximum permissible value, second worker - of 1,7 rem (17 mSv) and the third worker received a dose of 1 rem (10 mSv).

Category: Power Reactor Bilibino Russian Federation »

INES-event
INES 3

RADIOACTIVE WATER SPILLAGE ON THE PLANT TERRITORY WHILE TRANSPORTING CASK WITH FUEL FRAGMENTS TO THE DRY RADWASTE REPOSITORY

Effort was in progress at the plant to remove from the spent fuel pool (SFP) and transport to the radwaste repository a piece of fuel assembly (FA) cask with fuel fragments detected 31.01.91 while performing scheduled activity to reload spent FAs from SFP-3 to SFP-1.