INES-event
INES 1

COOLANT RADIOACTIVITY EXCEEDING OPERATING LIMITS DUE TO FUEL ROD FAILURE

Angra-1 had been experiencing some small fuel rods leakage since 4 months with primary water coolant activity indicating some percentage of Tech. Spec. limits. In 93.03.05 during a normal operation at 50% rated power a routine surveillance of reactor coolant activity detected values greater than the corresponding limiting conditions for operation. According to required actions the plant was immediately shut down following normal procedures. Preliminary estimations pointed out that around 100 fuel rods had failed. The utility is preparing defueling the core and inestigating the causes.
Basis for rating the event: 1) Event without an initiator (as per Table 1);
2) safety function challenged confining the radioactive material; 3) safety system operability (barrier - passive): less than minimum required by OL&C; 4) then safety function availability: adequate. rate selected: 1.

Location: ANGRA-1
Event date: Fri, 05-03-1993
Nuclear event report